Customization: | Available |
---|---|
Application: | Welding |
Voltage: | Low and Medium Voltage Cable |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Welding cables manufactured to IEC 245-6 (now IEC 60245-6) are flexible rubber-insulated single-core cables specifically designed for the secondary connection of electric arc welding equipment. These cables are constructed to endure high mechanical stress, repeated movement, flexing, and exposure to heat, oil, and abrasion.
Welding cables to IEC 245-6 are used in:
Electric arc welding machines for the connection to the electrode holder and ground clamp
Portable and mobile welding setups in:
Construction sites
Shipyards
Steel fabrication yards
Workshops and garages
Manual metal arc welding (MMA)
Gas-shielded metal arc welding (GMAW)
Other portable arc welding equipment
Component | Details |
---|---|
Conductor | Fine-stranded bare copper wire (Class 6 flexibility as per IEC 60228) |
Insulation | Rubber compound - heat, flame, and oil-resistant (e.g., EPR or synthetic elastomer) |
Sheath (if any) | May be single-layer insulation or include an additional rubber sheath |
Color | Typically black or orange for visibility and safety |
Temperature range | Usually from -25°C to +85°C or more depending on insulation material |
Note: The cable is highly flexible, suitable for frequent winding/unwinding.
Standard | Description |
---|---|
IEC 245-6 (obsolete) | Original standard for welding cables with rubber insulation (now superseded) |
IEC 60245-6 (current) | Rubber insulated cables - Rated up to 450/750 V - Part 6: Welding cables |
IEC 60228 | Conductors of insulated cables - Class 6 fine wire strands used for flexibility |
EN 50525-2-81 | European standard harmonized with IEC 60245-6 (for H01N2-D cable types) |
Cable Type: H01N2-D
Feature | Specification |
---|---|
Voltage Rating | 100 V (between conductor and earth), 100 V (between conductors) |
Max Operating Temp | 85°C (can vary by manufacturer) |
Flexibility Class | Class 6 (very flexible) |
Flame Retardant | Yes |
Oil Resistance | Yes |