Customization: | Available |
---|---|
Application: | Construction, Underground, Industrial, Power Station |
Voltage: | Low and Medium Voltage Cable |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Overview:
Our high-quality Medium Voltage (MV) Power Cable is designed to meet the most demanding requirements of electrical power transmission and distribution systems operating at 6/10kV. Engineered with cross-linked polyethylene (XLPE) insulation and polyvinyl chloride (PVC) sheathing, this cable offers superior electrical performance, thermal stability, mechanical strength, and fire resistance.
The cable adopts a single-core design, reinforced with Aluminium Wire Armour or Aluminium Tape Armour (AWA/ATA) for enhanced mechanical protection without compromising on electromagnetic performance. It is ideal for installations in power grids, substations, industrial plants, renewable energy systems, and urban infrastructure.
Rated Voltage: 6/10 kV (Um = 12kV)
Conductor Sizes: 25 mm² to 630 mm²
Construction: XLPE insulation + AWA/ATA+ PVC outer sheath
Application: Suitable for indoor/outdoor, direct burial, cable ducts or trays
Standards: IEC 60502-2, BS 6622, GB/T 12706.2
Armour Type: AWA (Aluminium Wire Armour)/ATA(Aluminium Type Armour) - optimal for single-core AC cables
Operating Temperature: Up to 90°C continuous; 250°C short-circuit (5s)
UV, moisture, chemical, and fire resistant
Low dielectric loss, long service life, excellent aging resistance
Parameter | Value/Range |
---|---|
Product Name | MV Power Cable XLPE/PVC 6/10kV |
Standard | IEC 60502-2, BS 6622, GB/T 12706.2 |
Rated Voltage | 6/10 kV |
Max System Voltage (Um) | 12 kV |
Conductor Material | Copper (Cu) or Aluminium (Al) |
Conductor Size | 25 mm² to 630 mm² |
Conductor Type | Single core, circular, compacted |
Insulation Material | XLPE (Cross-linked polyethylene) |
Armour Type | AWA - Aluminium Wire Armour/ATA-Aluminium Type Armour |
Outer Sheath | PVC - Black (UV/weather resistant) |
Operating Temperature | -15°C to +90°C |
Short Circuit Temp (5 sec) | Up to 250°C |
Installation Type | Direct burial, tray, duct, or free air |
Bending Radius | ≥15 × outer diameter |
Test Voltage (5 min) | 21 kV AC |
Flame Retardance |
Cat. A, B,C
|
Smoke Emission | Optional LSZH sheath per IEC 61034 |
Oil/Chemical Resistance | Good (based on outer sheath type) |
UV Resistance | Yes |
Certification | ISO, CE, RoHS, Type Test Report (on request) |
Layer | Description |
---|---|
Conductor | Plain annealed copper or aluminium, compacted circular, Class 2 (IEC 60228) |
Conductor Screen | Extruded semi-conductive layer |
Insulation | Cross-linked polyethylene (XLPE) |
Insulation Screen | Extruded semi-conductive layer |
Metallic Screen | Copper tape or concentric wires (optional) |
Separator/Binding | Non-hygroscopic bedding tape |
Armour | AWA - Aluminium Wire Armour (for mechanical protection in single-core cable) |
Outer Sheath | PVC (Polyvinyl Chloride), black (UV and weather resistant) |
Applications:
This cable is widely used in:
Primary and secondary distribution networks
Industrial and mining enterprises
Power plants and substations
Urban utility installations
Renewable energy projects (wind/solar farms)
Data centers and smart grid systems
Product Advantages:
Excellent dielectric properties with minimal loss.
Stable performance under high voltage stress and overload.
Can withstand continuous operation at 90°C, with emergency overload up to 130°C and short circuit conditions up to 250°C.
The AWA/ATA provides robust protection against mechanical impact during laying and service.
Outer sheath resists oil, chemicals, UV radiation, ozone, and mechanical abrasion.
Flame retardant according to IEC 60332-1.
Low smoke and toxic gas emission versions available upon request (LSZH sheath).
Available with various sheath colors, conductor materials (Cu/Al), and other custom specs.
Fully compliant with IEC, BS, GB standards.
Professional Export Team: Over 20 years of experience in international cable trade, serving clients in over 50 countries.
Reliable Manufacturing Base: Long-term partnerships with certified factories (ISO 9001/14001/45001) ensure quality and stable supply.
Fast Delivery: Standard production lead time is 15-20 working days. Emergency orders can be prioritized.
Strong After-sales Service: Technical support, third-party inspection (SGS/BV), and responsive customer service team.
OEM/ODM Available: Private labeling, customized packaging, and specifications as per your project requirements.
Supplied on wooden drum, steel drum, or steel-wood composite drum depending on cable type and length
Custom drum length and labeling available as per customer requirements
Fumigation-free export packaging available
Strong packaging ensures safe transport over long distances
Fast delivery within 10-20 working days after order confirmation
Looking for a trusted supplier of premium quality MV cables? Contact us today for:
Technical datasheets
Competitive quotations
Sample availability
OEM/ODM service options
Product Overview:
Our high-quality Medium Voltage (MV) Power Cable is designed to meet the most demanding requirements of electrical power transmission and distribution systems operating at 6/10kV. Engineered with cross-linked polyethylene (XLPE) insulation and polyvinyl chloride (PVC) sheathing, this cable offers superior electrical performance, thermal stability, mechanical strength, and fire resistance.
The cable adopts a single-core design, reinforced with Aluminium Wire Armour or Aluminium Tape Armour (AWA/ATA) for enhanced mechanical protection without compromising on electromagnetic performance. It is ideal for installations in power grids, substations, industrial plants, renewable energy systems, and urban infrastructure.
Rated Voltage: 6/10 kV (Um = 12kV)
Conductor Sizes: 25 mm² to 630 mm²
Construction: XLPE insulation + AWA/ATA+ PVC outer sheath
Application: Suitable for indoor/outdoor, direct burial, cable ducts or trays
Standards: IEC 60502-2, BS 6622, GB/T 12706.2
Armour Type: AWA (Aluminium Wire Armour)/ATA(Aluminium Type Armour) - optimal for single-core AC cables
Operating Temperature: Up to 90°C continuous; 250°C short-circuit (5s)
UV, moisture, chemical, and fire resistant
Low dielectric loss, long service life, excellent aging resistance
Parameter | Value/Range |
---|---|
Product Name | MV Power Cable XLPE/PVC 6/10kV |
Standard | IEC 60502-2, BS 6622, GB/T 12706.2 |
Rated Voltage | 6/10 kV |
Max System Voltage (Um) | 12 kV |
Conductor Material | Copper (Cu) or Aluminium (Al) |
Conductor Size | 25 mm² to 630 mm² |
Conductor Type | Single core, circular, compacted |
Insulation Material | XLPE (Cross-linked polyethylene) |
Armour Type | AWA - Aluminium Wire Armour/ATA-Aluminium Type Armour |
Outer Sheath | PVC - Black (UV/weather resistant) |
Operating Temperature | -15°C to +90°C |
Short Circuit Temp (5 sec) | Up to 250°C |
Installation Type | Direct burial, tray, duct, or free air |
Bending Radius | ≥15 × outer diameter |
Test Voltage (5 min) | 21 kV AC |
Flame Retardance |
Cat. A, B,C
|
Smoke Emission | Optional LSZH sheath per IEC 61034 |
Oil/Chemical Resistance | Good (based on outer sheath type) |
UV Resistance | Yes |
Certification | ISO, CE, RoHS, Type Test Report (on request) |
Layer | Description |
---|---|
Conductor | Plain annealed copper or aluminium, compacted circular, Class 2 (IEC 60228) |
Conductor Screen | Extruded semi-conductive layer |
Insulation | Cross-linked polyethylene (XLPE) |
Insulation Screen | Extruded semi-conductive layer |
Metallic Screen | Copper tape or concentric wires (optional) |
Separator/Binding | Non-hygroscopic bedding tape |
Armour | AWA - Aluminium Wire Armour (for mechanical protection in single-core cable) |
Outer Sheath | PVC (Polyvinyl Chloride), black (UV and weather resistant) |
Applications:
This cable is widely used in:
Primary and secondary distribution networks
Industrial and mining enterprises
Power plants and substations
Urban utility installations
Renewable energy projects (wind/solar farms)
Data centers and smart grid systems
Product Advantages:
Excellent dielectric properties with minimal loss.
Stable performance under high voltage stress and overload.
Can withstand continuous operation at 90°C, with emergency overload up to 130°C and short circuit conditions up to 250°C.
The AWA/ATA provides robust protection against mechanical impact during laying and service.
Outer sheath resists oil, chemicals, UV radiation, ozone, and mechanical abrasion.
Flame retardant according to IEC 60332-1.
Low smoke and toxic gas emission versions available upon request (LSZH sheath).
Available with various sheath colors, conductor materials (Cu/Al), and other custom specs.
Fully compliant with IEC, BS, GB standards.
Professional Export Team: Over 20 years of experience in international cable trade, serving clients in over 50 countries.
Reliable Manufacturing Base: Long-term partnerships with certified factories (ISO 9001/14001/45001) ensure quality and stable supply.
Fast Delivery: Standard production lead time is 15-20 working days. Emergency orders can be prioritized.
Strong After-sales Service: Technical support, third-party inspection (SGS/BV), and responsive customer service team.
OEM/ODM Available: Private labeling, customized packaging, and specifications as per your project requirements.
Supplied on wooden drum, steel drum, or steel-wood composite drum depending on cable type and length
Custom drum length and labeling available as per customer requirements
Fumigation-free export packaging available
Strong packaging ensures safe transport over long distances
Fast delivery within 10-20 working days after order confirmation
Looking for a trusted supplier of premium quality MV cables? Contact us today for:
Technical datasheets
Competitive quotations
Sample availability
OEM/ODM service options